Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
A Retrospective Study of Implant Placement Lateral to the Inferior Alveolar Nerve (ILIAN) in Severely Atrophic Posterior Mandibular Ridges
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 43 , Issue 4
July/August 2023

Pages e173–e180


A Retrospective Study of Implant Placement Lateral to the Inferior Alveolar Nerve (ILIAN) in Severely Atrophic Posterior Mandibular Ridges

Stuart J. Froum, DDS/Natacha Reis, DDS/Tanatcha Kukiratirat, DDS/Eduardo Gonzaléz De La Torre, DDS/Adam Barsoum, DMD/Paul Yung Chen Yu, DDS/Maryse Manasse, BSc, DMD, MEd/Sang-Choon Cho, DDS


DOI: 10.11607/prd.5625

Currently, several techniques are used in the posterior mandible to increase alveolar bone height and width. However, each has potential complications and limitations. The purpose of the current study was to present the surgical technique and restorative considerations for implant placement lateral to the inferior alveolar nerve (IAN) in cases of severely atrophic edentulous posterior mandibles. In total, 26 implants were successfully placed lateral to the IAN in 16 patients and restored with splinted screw-retained prostheses. The postloading follow-up time ranged between 3 months and 6 years. Two patients reported complications: One patient had a temporary paresthesia that resolved 3 months after implant placement, and the second patient had minor paresthesia that was reduced after implant removal but remained in a small area on the left corner of her lip.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help